Bypass Feature
The T-TECH bypass feature allows new ATF to loop within the vehicle
when the exchange is complete and the piston is at the top of the
cylinder. This feature allows the operator to walk away (work on
something else, etc.) when the machine is running, without being
concerned about service completion. When the piston reaches the top
of the cylinder (old ATF has displaced all of the new ATF), the bypass
feature is automatically engaged. This causes the new fluid to be forced
into a loop through the vehicle and the
T-TECH unit. The bypass will
continue until stopped when the operator turns the vehicle OFF.
Replace Existing New ATF with Different
New ATF
Use this procedure to replace a new fluid type that is already in the
cylinder with another type of new fluid needed to perform a current
service (e.g. the cylinder is currently filled with DEXRON III but you need
to service a Chrysler that uses MOPAR+ fluid).
To accomplish this task, the piston will be pushed to the top of the
cylinder to force any existing new ATF into a clean storage container so the fluid can be reused. See Figure 61.
1. Set CONTROL VALVE to SERVICE VEHICLE.
2. Attach a service hose adapter to each service transfer hose.
3. Insert one service hose adapter into a clean container to save the fluid that is to be removed from the
cylinder.
4. Insert your air nozzle into the open end of the other service hose adapter.
5. Apply air pressure (air pressure should be above 10 psi but should not exceed 20 psi on the system
pressure gauge).
6. The machine will sense the pressure and the piston should begin to rise. As the piston nears the top of the
cylinder, ease back on the air pressure.
7. When the piston reaches the top of the cylinder,
hold the air nozzle and service hose adapter in a
waste container with the service adapter pointing
away from any personnel. Pressurized air and
possibly some ATF will be expelled out of the end
of the service hose adapter when the air is
released and the line hose is removed.
8. Release the air pressure and remove the nozzle
from the service hose adapter.
9. Refill the cylinder with new ATF fluid of the type
required to perform the service according to FILL
CYLINDER FUNCTION. Make sure to fill the
cylinder until the cylinder is completely full of ATF
to avoid any air pockets under the piston.
T-TECH
FITTINGS
Fluid Exchange
Complete – Turn
Vehicle Off
Cylinder Is Now
Filled With Old Fluid
Figure 51. Exchange Of Fluids Complete
Service
Transfer
Hoses
Waste
Disposal
Container
Service
Hose
Adapter
ATF
Container
Service
Hose
Adapter
Air
Hose
TECHT
-
®
Failure to follow instructions may cause damage or explosion;
always shield eyes. Read entire instruction manual before use.
WARNING
Do not exceed 75 PSI input pressure when filling the T-TECH.
CAUTION
Figure 52. Exchange New Fluids